Operating Voltage: 1.8V ~ 5.5V
Average Operating Current: 5.5uA (Typical, @3.3V, 1 temperature and humidity conversion per second)
Standby Current: 0.36μA (Typical)
Temperature Accuracy (Factory Calibrated):
10℃ ~ 50℃: ±0.1℃ (Typical), ±0.3℃ (Maximum)
0℃ ~ 85℃: ±0.2℃ (Typical), ±0.6℃ (Maximum)
-40℃ ~ 125℃: ±0.5℃ (Typical), ±1.0℃ (Maximum)
Humidity Accuracy (Factory Calibrated): 20%RH ~ 80%RH: ±2.0%RH (Typical), ±4.0%RH (Maximum)
Digital interface compatible with SMBus and I²C, supporting the following functions:
PEC (Packet Error Checking) function to enhance communication reliability and robustness
Maximum communication speed up to 1.0MHz
SMBus General Call
Supports One-shot Measurement and Continuous Measurement modes
NIST traceable calibration
Temperature Measuring Range: -40℃ ~ 125℃
Humidity Measuring Range: 0%RH ~ 100%RH