l Operation Voltage: 2.1V to 5.5V
l Operating Current: 30uA during Temperature conversion;
l Average Consumption Current: 1.0uA (Typ.) with reading once temperature per second
l Standby Current: 50nA(Typ.), 200nA (Max.)
l Temperature Conversion time:30ms at 13-bit
l Temperature Accuracy without calibration:
±0.5oC(Max.) from -10oC to 80oC
l 13 bit ADC for 0.0625oC resolution
l Compatible with 1-wire interface
l 768-bit Available EEPROM
l 24-bit user ID instead of 64-bit ROM ID for quick search, match and Alarm search
l Temperature Range: -40oC to 125oC
l Package: TO-92, TO-92S-2,SOT-23-3