l Operation Voltage: 1.75V to 5.5V
l Average Operating Current: 45uA (Typ.)for all channels one time measurement at VCC = 3.3V
l Standby Current: 3.0uA (Typ.)
l Temperature Accuracy without calibration for all channels:±1oC from 0oC to 50oC
l 13 bit ADC for 0.0625oC resolution
l Digital interface compatible with SMBus and I2C
l Series Resistance Cancellation, n-Factor correction, Offset correction and Diode fault detection for each remote channel.
l Individually programmable THERM limit temperature for any of 9 channels with share Hysterisis data
l Register lock feature to protect register data
l 8 slave addresses available by setting AD0 pin
l Temperature Range:
-40oC to 125oC for local channel
-200oC to 200oC for remote channels
l The measurement range can be extended from -200 oC to 200 oC for remote channels with 9018 transistor.